EXTECH EX810 1000A Clamp Meter with IR : Clamp-on multimeter with built-in non-contact InfraRed Thermometer
EXTECH EX810-NISTL 1000A Clamp Meter with IR with NIST : Clamp-on multimeter with built-in non-contact InfraRed Thermometer NISTL Certificate Included.
EXTECH EX810-NIST 1000A Clamp Meter with IR with NIST : Clamp-on multimeter with built-in non-contact InfraRed Thermometer
Features:
- AC Current
- Average Responding
- Non-contact InfraRed Temperature measurements with laser pointer
- Peak hold captures inrush currents and Transients
- MultiMeter functions include
- AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, and Continuity
- 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
- 4000 count backlit dual display
- Features include Data Hold and Min/Max
- Autoranging with manual range button
- Auto Power off
General Specifications |
IR Temperature |
-58 to 518ºF -50 to 270ºC |
AC Current |
0.1 to 1000A |
DC Current |
NA |
AC Voltage |
0.1mV to 600V |
DC Voltage |
0.1mV to 600V |
Resistance |
0.1 to 40M Ω; |
Capacitance |
0.001nF to 40,000µF |
Frequency |
0.001kHz to 4kHz |
Type K Temperature |
NA |
Continuity |
Yes |
Inrush |
Yes |
Diode |
Yes |
Dimensions/Wt. |
10.6x4.3x2" (270x110x50mm) |
Weight |
13.6oz (386g) |
|
|
EXTECH EX830 1000A Clamp Meters with IR Thermometer : Clamp-on multimeter with built-in non-contact InfraRed Thermometer
EXTECH EX830-NISTL 1000A Clamp Meters with IR Thermometer with NIST : Clamp-on multimeter with built-in non-contact InfraRed Thermometer NISTL Certificate Included
Features:
- AC Current
- True RMS
- Type K Thermometer
- DC Zero
- Non-contact InfraRed Temperature measurements with laser pointer
- Peak hold captures inrush currents and Transients
- MultiMeter functions include
- AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, and Continuity
- 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
- 4000 count backlit dual display
- Features include Data Hold and Min/Max
- Autoranging with manual range button
- Auto Power off
- Complete with test leads, 9V battery, Type K probe (-4 to 482°F/-20 to 250°C), and belt holster
General Specifications |
IR Temperature |
-58 to 518ºF -50 to 270ºC |
AC Current |
0.1 to 1000A |
DC Current |
0.1 to 1000A |
AC Voltage |
0.1mV to 600V |
DC Voltage |
0.1mV to 600V |
Resistance |
0.1 to 40M Ω; |
Capacitance |
0.001nF to 40,000µF |
Frequency |
0.001kHz to 4kHz |
Type K Temperature |
-4 to 1400°F -20 to 760°C |
Continuity |
Yes |
Inrush |
Yes |
Diode |
Yes |
Dimensions/Wt. |
10.6x4.3x2" (270x110x50mm) |
Weight |
13.6oz (386g) |
|
|
EXTECH 382097 100A Current Clamp Probes Set of 3 Current Clamp Probes
Description:
382097: 100A Current Clamp Probes Set of 3 Current Clamp Probes Features:
■1.2" (30mm) jaw size
■100A Max Current
|
|
EXTECH MA150-NIST 200A Mini AC Clamp Meter + NCV Detector : Compact size AC Clamp meter with built-in AC Voltage detector and Flashlight NIST Certificate Included.
EXTECH MA150 200A Mini AC Clamp Meter + NCV Detector : Compact size AC Clamp meter with built-in AC Voltage detector and Flashlight
Description:
MA150: 200A Mini AC Clamp Meter + NCV Detector Compact size AC Clamp meter with built-in AC Voltage detector and Flashlight Features:
■0.7" (18mm) jaw opening
■2000 count backlit LCD display
■Non-contact AC Voltage detector (100 to 600VAC) via clamp tip
■Built-in white LED flashlight
■Continuity and Diode Test, Max Hold, Auto power off
■NIST Certificate Included.
|
|
EXTECH AM300-NIST 300A AC Analog Clamp Meter : Analog AC Clamp Meter with Rotary Scale and Pointer Lock NIST Certificate Included.
EXTECH AM300 300A AC Analog Clamp Meter : 300A AC Analog Clamp Meter Analog AC Clamp Meter with Rotary Scale and Pointer Lock
* Single function/range switch for easy one hand operation * Rotary Scale with Pointer Lock freezes the reading on the display * Jaw opens to 1.5" (38mm) * AC/DC Voltage and Resistance measurement * Zero adjust *NIST Certificate Included.
|
|
EXTECH MA200-NIST 400A AC Clamp Meter NIST Certificate Included.
EXTECH MA200 400A AC Clamp Meter
General Specifications |
AC Current |
2, 20, 200, 400A (0.001A) |
DC Current |
NA |
Basic accuracy |
±2.5% |
DC Voltage |
200mV, 2V, 20, 200V, 600V (0.1mV) |
AC Voltage |
200mV, 2V, 20V, 200V, 600V (0.1mV) |
Basic accuracy |
AC: ±1.5% DC: ±1.2% |
Resistance (?;) |
200, 2k, 20k, 200k, 2M, 20M (0.1 ‰ ) |
Capacitance |
NA |
Frequency |
NA |
Temperature |
NA |
Duty Cycle |
NA |
Continuity |
Beeper =30 ?; |
Power |
Two AAA batteries |
Dims/Wt. |
7.9x2x1.4" (200x50x35mm)/ 7oz |
|
|
EXTECH MA220 400A AC/DC Clamp Meter : Functions include Capacitance, Frequency, Temperature, and Duty Cycle
EXTECH MA220-NIST 400A AC/DC Clamp Meter : Functions include Capacitance, Frequency, Temperature, and Duty Cycle NIST Certificate Included.
General Specifications |
AC Current |
2, 20, 200, 400A (0.001A) |
DC Current |
40, 400A (0.01A) |
Basic accuracy |
±2.5% |
DC Voltage |
200mV, 2V, 20, 200V, 600V (0.1mV) |
AC Voltage |
200mV, 2V, 20V, 200V, 600V (0.1mV) |
Basic accuracy |
AC: ±1.5% DC: ±1.2% |
Resistance (Ω;) |
200, 2k, 20k, 200k, 2M, 20M (0.1 ‰ ) |
Capacitance |
40nF, 400nF, 4μF, 40μF, 100μF (0.01nF) |
Frequency |
5Hz, 50Hz, 500Hz, 5kHz, 150kHz (0.001Hz) |
Temperature |
-58 to 1830°F (-50 to 1000°C) (1°) |
Duty Cycle |
0.5 to 99.0% (0.1%) |
Continuity |
Beeper ≤30 Ω; |
Power |
Two AAA batteries |
Dims/Wt. |
7.9x2x1.4" (200x50x35mm)/ 7oz |
|
|
EXTECH DC400 400A DC Mini Clamp Meter : Ideal for automotive, heavy equipment and marine DC current measurements
Description:
DC400: 400A DC Mini Clamp Meter Ideal for automotive, heavy equipment and marine DC current measurements Features:
■High Accuracy and Resolution
■One touch "Auto Zero"
■Large 4000 count LCD display
■Easy to use, single function meter |
|
EXTECH EX612 400A Dual Input AC Clamp Meter + NCV : AC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector.
EXTECH EX612-NIST 400A Dual Input AC Clamp Meter + NCV : AC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector NIST Certificate Included.
Description:
EX612: 400A Dual Input AC Clamp Meter + NCV AC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector Features:
■True RMS measurements for accurate AC Voltage and Current measurements
■Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2) ■Built-in non-contact Voltage detector with LED alert
■DC µA multimeter function for HVAC flame rod Current measurements
■Data Hold plus fast Peak Hold of current surges during motor startup
■40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
■Measures motor capacitors to 40,000µF
■1.25" (32mm) jaw opening for conductors up to 500MCM
■Rugged double molded housing
■Auto power off with audible alert and disable function
■Autoranging with manual override
■Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes and case |
|
EXTECH EX622-NISTL AC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer NIST Certificate Included.
EXTECH EX622 AC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer
Description:
EX622: 400A Dual Input AC Clamp Meter + NCV + IR Thermometer AC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer Features:
■True RMS measurements for accurate AC Voltage and Current measurements
■Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2) ■Built-in non-contact IR Thermometer with laser pointer for locating hot spots (up to 518°F/270°C)
■Built-in non-contact Voltage detector with LED alert
■DC µA multimeter function for HVAC flame rod Current measurements
■Data Hold plus fast Peak Hold of current surges during motor startup
■40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
■Measures motor capacitors to 40,000µF
■1.25" (32mm) jaw opening for conductors up to 500MCM
■Rugged double molded housing
■Auto power off with audible alert and disable function
■Autoranging with manual override
■8 to 1 distance to target ratio
■Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes and case |
|
EXTECH EX613 400A Dual Input AC/DC Clamp Meter + NCV : AC/DC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector.
EXTECH EX613-NIST 400A Dual Input AC/DC Clamp Meter + NCV : AC/DC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector NIST Certificate Included.
Description:
EX613: 400A Dual Input AC/DC Clamp Meter + NCV AC/DC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector Features:
■True RMS measurements for accurate AC Voltage and Current measurements
■Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2) ■Built-in non-contact Voltage detector with LED alert
■DC µA multimeter function for HVAC flame rod Current measurements
■Data Hold plus fast Peak Hold of current surges during motor startup
■40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
■Measures motor capacitors to 40,000µF
■1.25" (32mm) jaw opening for conductors up to 500MCM
■Rugged double molded housing
■Auto power off with audible alert and disable function
■Autoranging with manual override
■Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes and case
|
|
EXTECH EX623 400A Dual Input AC/DC Clamp Meter + NCV + IR Thermometer : AC/DC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer. This product is the winner of HKEIA 2008 Gold Award
Description:
EX623: 400A Dual Input AC/DC Clamp Meter + NCV + IR Thermometer AC/DC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer This product is the winner of HKEIA 2008 Gold Award Features:
■True RMS measurements for accurate AC Voltage and Current measurements
■Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2)
■Built-in non-contact IR Thermometer with laser pointer for locating hot spots (up to 518°F/270°C)
■Built-in non-contact Voltage detector with LED alert
■DC µA multimeter function for HVAC flame rod Current measurements
■Data Hold plus fast Peak Hold of current surges during motor startup
■40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
■Measures motor capacitors to 40,000µF
■1.25" (32mm) jaw opening for conductors up to 500MCM
■Rugged double molded housing
■Auto power off with audible alert and disable function
■Autoranging with manual override
■8 to 1 distance to target ratio
■Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes and case
|
|
EXTECH EX600 Series: 400A Dual Input AC Clamp Meter + NCV
Common Features:
• True RMS measurements for accurate AC Voltage and Current measurements
• Dual type K thermocouple input with Differential Temperature function
(T1, T2, T1-T2)
• Built-in non-contact Voltage detector with LED alert
• DC μA multimeter function for HVAC flame rod Current measurements
• Data Hold plus fast Peak Hold of current surges during motor startup
• 40,000 count multimeter functions for DC Voltage, Resistance, Capacitance,
and Frequency for high resolution over wider ranges
• Measures motor capacitors to 40,000μF
• 1.4" (36mm) jaw opening for conductors up to 500MCM
• Rugged double molded housing
• Auto power off with audible alert and disable function
• Autoranging with manual override
• Complete with CAT III-600V, double molded test leads, 9V battery, two Type
K bead wire probes (-22 to 572°F/-30 to 300°C), and case
|
|
EXTECH AM600 : 600A AC Analog Clamp Meter NIST Certificate Included. Analog AC Clamp Meter with built-in Temperature function
* Temperature function to measure operating temperature of motors and other electrical devices * Jaw opens to 1.3" (34mm) * AC/DC Voltage and Resistance measurement * Pointer Lock freezes reading on display *NIST Certificate Included.
|
|
EXTECH 38387 : Clamp meter includes AC/DC Voltage and Resistance measurements.
Features:
- Peak Hold for in-rush Currents
- Data Hold
- Auto power off
Description
Clamp meter includes AC/DC Voltage and Resistance measurements. Properly used, this meter will provide many years of reliable service.
General |
AC Voltage |
600 VAC ± (1.5% + 4 digits) at 50/60Hz |
DC Voltage |
600 VDC ± (1.0% + 1 digits) |
Resistance |
1999 Ω ± (1.0% + 2 digits) |
Jaw size Opening |
1.3" (33mm) approx. |
Display |
3-1/2 digits (2000 counts) LCD |
Continuity Audible tone |
< 40 Ω approx. |
AC bandwidth |
40Hz to 400Hz |
Safety compliance |
IEC 1010-1 and VDE 0411 |
Operating Temperature |
32 to 122°F (0 to 50°C) |
Storage Temperature |
-4 to 140°F (-20 to 60°C) |
Over voltage |
Cat II 600V |
Overload protection |
250V AC/DC Spark Gap protection, PTC protection for Ω range to 250V |
Battery |
9V battery (IEC 6F22) |
Auto Power OFF |
After 10 minutes of inactivity |
Dimensions/Weight |
8x3.2x1.7" (204x80x43mm)/0.62 lbs. (281g) |
|
|
EXTECH 38394 This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance, Frequency, and Continuity.
EXTECH 38394-NIST This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance, Frequency, and Continuity.
Features:
- Also measures Voltage, Resistance, and Frequency
- Auto or manual ranging
- Relative function zeros Current measurements or creates a reference value
- Data Hold
Description
This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance, Frequency, and Continuity. Proper use and care of this meter will yield years of reliable service.
General |
Conductor Size |
1.18" (30mm) maximum |
Battery type |
2 x 1.5V AA |
Range Selection |
Automatic ranging |
Display |
5000 Count LCD |
Overload Indication |
"OL" |
Low Battery Indication |
Battery icon |
Environmental conditions |
Installation Category II, Pollution degree |
Altitude |
2000 meters, Indoor use only |
Operating Temperature/Humidity |
32° to 122°F (0°C to 50°C) / <80% RH |
Storage Temperature/Humidity |
14° to 140°F (-10°C to 60°C) / <80% |
Dimensions |
7.0x4.2x1.3? (178x64x33mm) |
Weight |
8.3 oz. (230g) |
Zero Adjust |
Uses REL (Relative) push button |
Diode |
Short/Open, Good/Defect Test |
Sample Time |
0.35 sec approximately. |
Input Impedance |
10M Ω for ACV & DCV |
|
|
EXTECH EX710 Extech EX710 EX700 Series. Functions include Capacitance and Temperature
EXTECH EX710-NIST Extech EX710 w/ NIST EX700 Series. Functions include Capacitance and Temperature
Features:
- AC Current, AC/DC Voltage, Resistance, Frequency, Capacitance, Temperature, Diode, and Continuity
- Peak function captures inrush currents and voltage transients
- Data Hold “freezes” data in display
- 1.2" (30mm) circular jaw opening forlarge cables (500MCM)
- Auto power off
- Complete with test leads, 9V battery, and carrying case
Description
Functions include Capacitance and Temperature.
General Specifications |
AC Current |
0.01 to 800A |
DC Current |
NA |
AC Voltage |
0.1mV to 600V |
DC Voltage |
0.1mV to 600V |
Resistance |
0.1 to 40M ?; |
Capacitance |
0.001nF to 40,000µF |
Frequency |
0.001 to 4kHz |
Temperature Type K |
NA |
Continuity |
Yes |
Inrush |
Yes |
Diode |
Yes |
Dimensions |
9x3.1x1.9" (229x80x49mm) |
Weight |
10.7 oz (303g) |
|
|
EXTECH EX720 800A Clamp Meter True RMS
EXTECH EX720-NIST 800A Clamp Meter True RMS with NIST
Features:
- True RMS
- AC Current, AC/DC Voltage, Resistance, Frequency, Capacitance, Temperature, Diode, and Continuity
- Peak function captures inrush currents and voltage transients
- Data Hold “freezes” data in display
- 1.2" (30mm) circular jaw opening forlarge cables (500MCM)
- Auto power off
- Complete with test leads, 9V battery, Type K bead wire probe, and carrying case
Description
Functions include Capacitance and Temperature.
General Specifications |
AC Current |
0.01 to 800A |
DC Current |
NA |
AC Voltage |
0.1mV to 600V |
DC Voltage |
0.1mV to 600V |
Resistance |
0.1 to 40M ?; |
Capacitance |
0.001nF to 40,000µF |
Frequency |
0.001 to 4kHz |
Temperature Type K |
-4 to 1400°F -20 to 760°C |
Continuity |
Yes |
Inrush |
Yes |
Diode |
Yes |
Dimensions |
9x3.1x1.9" (229x80x49mm) |
Weight |
10.7 oz (303g) |
|
|
EXTECH EX730 800A Clamp Meter True RMS/DC
EXTECH EX730-NIST 800A Clamp Meter True RMS/DC with NIST
Features:
- True RMS
- DC Zero
- AC/DC Current, AC/DC Voltage, Resistance, Frequency, Capacitance, Temperature, Diode, and Continuity
- Peak function captures inrush currents and voltage transients
- Data Hold “freezes” data in display
- 1.2" (30mm) circular jaw opening forlarge cables (500MCM)
- Auto power off
- Complete with test leads, 9V battery, Type K bead wire probe, and carrying case
Description
Functions include Capacitance and Temperature.
General Specifications |
AC Current |
0.01 to 800A |
DC Current |
0.1 to 800A |
AC Voltage |
0.1mV to 600V |
DC Voltage |
0.1mV to 600V |
Resistance |
0.1 to 40M ?; |
Capacitance |
0.001nF to 40,000µF |
Frequency |
0.001 to 4kHz |
Temperature Type K |
-4 to 1400°F -20 to 760°C |
Continuity |
Yes |
Inrush |
Yes |
Diode |
Yes |
Dimensions |
9x3.1x1.9" (229x80x49mm) |
Weight |
10.7 oz (303g) |
|
|
EXTECH 380950 80A Mini AC/DC Clamp Meter Small diameter elongated jaw fits into tight spaces
Features:
• 4000 count LCD display
• 4A range with 1mA resolution for accurate low current measurements
• Jaw opens to 0.5" (12.7mm)
• AC/DC Voltage, Resistance, Frequency,Capacitance, and Duty Cycle
• Diode Test/Continuity Beeper
• Data Hold and Max Hold
• Complete with test leads, 9V battery,and carrying case |
|
EXTECH MA100 AC Mini Clamp Meter/Voltage Detector
EXTECH MA100-NIST Convenient compact size clamp meter with built-in AC Voltage detector. Includes NIST Certificate.
Features:
- Measures 200A AC Current up to 100mA resolution
- 3% basic ACA accuracy
- 0.7" (18mm) jaw opening; 300MCM cable size
- 2000 count LCD display
- Non-contact AC Voltage detector (120/240VAC, 50/60Hz) via clamp tip
- Built-in white LED flashlight
- Measures Frequency up to 1kHz with 0.01Hz resolution
- Autoranging with Auto Power Off
- Data Hold
- Overload protection for all ranges
- Overrange and low battery indicators
- Complete with two AAA batteries
Description
Convenient compact size clamp meter with built-in AC Voltage detector.
General |
AC Current |
200A |
DC Current |
NA |
Max Resolution |
0.1A |
Basic ACA Accuracy (%rdg) |
±3% |
AC Voltage (Max Res.) |
Non-contact |
Frequency (Max Res.) |
NA |
Dimensions |
6.5x2.6x1.3" (164x65x32mm) |
Weight |
6.2 oz (176g) |
|
|
EXTECH MA120 AC/DC Mini Clamp Meter+Voltage Detector
EXTECH MA120-NIST AC/DC Mini Clamp Meter+Voltage Detector with NIST
Features:
- 200A AC/DC Current
- Frequency measurment
- DCA zero key and backlit display
- Measures 200A AC Current up to 100mA resolution
- 3% basic ACA accuracy
- 0.7" (18mm) jaw opening; 300MCM cable size
- 2000 count LCD display
- Non-contact AC Voltage detector (120/240VAC, 50/60Hz) via clamp tip
- Built-in white LED flashlight
- Measures Frequency up to 1kHz with 0.01Hz resolution
- Autoranging with Auto Power Off
- Data Hold
- Overload protection for all ranges
- Overrange and low battery indicators
- Complete with two AAA batteries
Description
Convenient compact size clamp meter with built-in AC Voltage detector.
General Specifications |
AC Current |
200A |
DC Current |
200A |
Max Resolution |
0.1A |
Basic ACA Accuracy (%rdg) |
±3% |
AC Voltage (Max Res.) |
Non-contact |
Frequency (Max Res.) |
1kHz (0.01Hz) |
Dimensions |
6.5x2.6x1.3" (164x65x32mm) |
Weight |
6.2 oz (176g) |
|
|
EXTECH CA200 CLAMP ADAPTOR, 200A AC : AC Current measurements, no battery required
Description:
AC Current measurements, no battery required |
0.62" (16mm) clamp jaw
1mV AC output per Amp
±2% basic accuracy
CAT II-600V, CAT III-300V
Complete with built-in 5.3ft (163cm) cable with banana plugs |
|
|
EXTECH 382357 Clamp-on Ground Resistance Tester : Non-contact measurements of ground conductors without need for auxiliary ground spikes
Description:
382357: Clamp-on Ground Resistance Tester Non-contact measurements of ground conductors without need for auxiliary ground spikes Features:
■Autoranging ground resistance measurements from 0.025Ohm to 1500Ohm with 0.002Ohm resolution
■True RMS AC Leakage current range of 0.2mA to 30A with 1.000mA resolution
■Programmable Datalogging with 116 data points
■Programmable Hi/Lo Alarm
■0.9" (23mm) Jaw size for large ground rods
|
|
EXTECH EX840 CLAMP DMM + IR THERM TRMS 1000 AMP AC/DC
Features:
- Non-contact IR Temperature measurements with laser pointer
- True RMS Current and Voltage measurements
- Peak hold captures inrush currents and Transients
- Multimeter functions: AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, and Continuity
- 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
- 4000 count backlit display
- Data Hold and Min/Max, Auto Power off
- Complete with standard test leads, 9V battery, Type K probe (-22 to 572°F/-30 to 300°C), belt holster, and professional CAT III-1000V Test Leads
|
|
EXTECH 380974-NIST : This professional 1000A Clamp meter also provides phase rotation testing where motor direction (clockwise or counter-clockwise) and phase sequences can be displayed
General Specifications |
Clamp jaw size |
1.6? (40mm) |
Battery type |
9V |
Range Selection |
Manual |
Display |
3 3/4 digit (4000 count) multi-function LCD with 40-segment bargraph indication |
Overload Indication |
?OL? displays on LCD |
Power |
9V battery (200 hour life typical) |
Low Battery Indication |
Battery icon displays on LCD |
Auto Power Off |
After 30 minutes (feature can be disabled) |
Display update rate |
1.3 updates/second (digital display), 13.3 updates/second (bargraph) |
Operating Temperature / RH |
32 to 122°F (0°C to 50°C) / <80% |
Storage Temperature / RH |
14 to 140°F (-10°C to 60°C) / <70% |
Dimensions/Weight |
9 x 3 x 1.5? (228 x 76 x 39mm) / 13 oz. (370g) |
Overload Protection |
AC Current, Frequency (clamp) |
1100A |
AC Voltage, Sequence, Resistance, Capacitance, Frequency (leads) |
600V rms |
|
|
EXTECH 382068 : 1000A True RMS Clamp-on Power Datalogger Measurements include DC and AC True Power, Apparent Power, Power Factor, and True RMS Voltage, Current, Watts.
General Specifications |
Main display |
4-digit (10,000 count) multi-function LCD |
Bargraph display |
40-segment bargraph |
Datalogger |
4000 data point continuous logging (25 point manual logging) with MIN / MAX and Peak detect recording |
Peak hold |
Built-in detector captures positive and negative peaks to .1ms |
Maximum voltage |
600Vrms between any terminal and earth ground |
Meter power |
9V battery |
Battery life |
30 hours (approx.) |
Low battery indication |
Battery icon is displayed |
Auto power off |
After 30 minutes (approx.) |
Display update rate |
2 times per second (Bargraph); 5 times per second (Digits), (once every 6 seconds for the KW function) |
Jaw opening For Cables |
φ 1.8? (46mm) |
Operating temperature |
32 to 122°F (0 to 50°C) |
Operating Humidity R.H. |
< 80% non-condensing. |
Storage temperature |
14°to 140°F (-10 to 60°C) |
Storage Humidity RH |
< 70% non-condensing |
Dimensions/Weight |
10.24 x 3.66 x 1.77" (260 x 93 x 45mm) / 1 lb. (450g) |
Accessories |
Carrying case, test leads, and 9V battery |
Range Specifications |
Accuracy |
Specs are ± (reading + no. of digits) at 64° to 82°F (18° to 28°C) and RH to 80% |
|
|
EXTECH 380905 : Extech 2000A AC/DC Clamp-on Adaptor
Features:
- 2.5" (64mm) clamp jaw opening (750MCM)
- Measures AC/DC Current in two ranges: 0 to 200A and 0 to 2000A and converts it to 1mV/count for reading current on any multimeter or voltage recorder
- Banana plugs connect into standard multimeter sockets and switch multimeter to a millivolt or voltage range
- Basic accuracy to 2% up to 200A, 3% to 1500A
- Zero adjust knob for optimizing accuracy
- Dimensions: 7.7 x 2.6 x 1.4"(195 x 66 x 35mm),
- Weight: 1.1lb (500g)
- Complete with built-in 1.8ft (570mm) cable with banana plugs and 9V battery
Description
Multimeter with AC/DC Current measurements. Careful use of this device will provide years of reliable service |
|
EXTECH 380941 : Economical clamp-on for reliable AC/DC Current measurements.
General Specifications |
Display |
0.5" (13mm), LCD, 3-1/2 digit (±1999 counts) |
Measurements |
AC/DC Voltage/Current and Resistance |
Polarity |
Automatic Switching; "-" indicates negative polarity |
Current Sensor |
Hall effect sensor |
Zero Adjustment |
Meter dial for DC Current zero |
Over-input |
Display indicates "1" or "-1" |
Sampling Time |
Approximately 0.4 seconds |
Time Base |
Quartz crystal (32768 Hz) |
Fuse Protection |
500mA fuse |
Battery |
006P DC 9V battery (heavy duty type) |
Power Consumption |
Approximately 6mADC (Voltage & Resistance), Approximately 12mADC (Current range) |
Operating Temp |
32 to 122 ° F (0 to 50 ° C) |
Operating Humidity |
Less than 80% RH |
Weight |
0.5 lbs. (225g) (including battery) |
Dimension |
7.1x1.9x1.4" (180x47x35mm) |
Max. conductor size |
19 f (19mm diameter) |
Accessories |
Instruction Manual, Test Leads, Carrying Case |
|
|
EXTECH 380652 Economical clamp-on for reliable AC/DC Current measurements.
EXTECH 380652-NIST Economical clamp-on for reliable AC/DC Current measurements
General Specifications |
Display |
0.5" (13mm), LCD, 3-1/2 digit (±1999 counts) |
Measurements |
AC/DC Voltage/Current and Resistance |
Polarity |
Automatic Switching; "-" indicates negative polarity |
Current Sensor |
Hall effect sensor |
Zero Adjustment |
Meter dial for DC Current zero |
Over-input |
Display indicates "1" or "-1" |
Sampling Time |
Approximately 0.4 seconds |
Time Base |
Quartz crystal (32768 Hz) |
Fuse Protection |
500mA fuse |
Battery |
006P DC 9V battery (heavy duty type) |
Power Consumption |
Approximately 6mADC (Voltage & Resistance), Approximately 12mADC (Current range) |
Operating Temp |
32 to 122 ° F (0 to 50 ° C) |
Operating Humidity |
Less than 80% RH |
Weight |
0.5 lbs. (225g) (including battery) |
Dimension |
7.1x1.9x1.4" (180x47x35mm) |
Max. conductor size |
19 φ (19mm diameter) |
Accessories |
Instruction Manual, Test Leads, Carrying Case |
|
|
EXTECH 380941-NIST Economical clamp-on for reliable AC/DC Current measurements.
General Specifications |
Display |
0.5" (13mm), LCD, 3-1/2 digit (±1999 counts) |
Measurements |
AC/DC Voltage/Current and Resistance |
Polarity |
Automatic Switching; "-" indicates negative polarity |
Current Sensor |
Hall effect sensor |
Zero Adjustment |
Meter dial for DC Current zero |
Over-input |
Display indicates "1" or "-1" |
Sampling Time |
Approximately 0.4 seconds |
Time Base |
Quartz crystal (32768 Hz) |
Fuse Protection |
500mA fuse |
Battery |
006P DC 9V battery (heavy duty type) |
Power Consumption |
Approximately 6mADC (Voltage & Resistance), Approximately 12mADC (Current range) |
Operating Temp |
32 to 122 ° F (0 to 50 ° C) |
Operating Humidity |
Less than 80% RH |
Weight |
0.5 lbs. (225g) (including battery) |
Dimension |
7.1x1.9x1.4" (180x47x35mm) |
Max. conductor size |
19 φ (19mm diameter) |
Accessories |
Instruction Manual, Test Leads, Carrying Case |
|
|
EXTECH 380942 : Extech 30A True RMS Mini Clamp-On Highest resolution and accuracy at low currents.
General Specifications |
Display |
3-3/4 (4000 count) Digit LCD with 40 segment bargraph |
Functions |
ACA, DCA, ACV, DCV |
Polarity |
Minus sign ( - ) indicates negative polarity |
Current sensor |
Hall effect sensor type |
Overload indication |
Left blinking digit |
DCA zero adjust |
One touch zero key |
Display rate |
2 readings/second (20 readings/second for bargraph) |
Battery |
Two 1.5V AA batteries |
Operating conditions |
4°F to 122°F (-10°C to 50°C), < 85% Relative Humidity |
Storage conditions |
- 4°F to 140°F (-20°C to 60°C); < 75% Relative Humidity |
Altitude |
Operate at less than 2000 meters. Indoor use only. |
Power consumption |
Approximately 10mA DC |
Weight |
6.2 oz. (190g) including battery |
Dimensions |
7.2 x 2.5 x 1.4? (183 x 63.6 x 35.6mm) (HWD) |
Jaw opening |
0.9? (23mm) |
Standards |
IEC 1010 Category III 300V, Category II 600V |
AC Voltage and Current Crest Factor |
< 3 |
AC / DC Voltage Input Impedance |
10M Ω |
|
|
EXTECH 380947 Extech 400A True RMS Mini-clamp : True RMS mini-clamp with high current resolution.
EXTECH 380947-NIST Extech 400A True RMS Mini-Clamp with NIST : True RMS mini-clamp with high current resolution.Included is the NIST Certificate.
General Specifications |
Display |
3-3/4 Digit LCD with 40 segment bargraph |
Functions |
Current (ACA, DCA) and Frequency (Hz) |
Polarity |
?-? indicates negative polarity (positive polarity assumed) |
Current sensor |
Hall effect |
Overload Display |
indicates ?1___? or ?-1___? |
DCA zero adjust |
One-touch zero key (also used as a Relative function) |
Display rate |
2 readings/second (20 readings/second for bargraph) |
Battery |
Two 1.5V AA batteries |
Operating temperature |
4°F to 122°F (-10°C to 50°C) |
Operating Humidity |
< 85% RH |
Power consumption |
10mA DC approx. |
Weight |
6.2 oz. (190g) including battery |
Dimensions |
7.2 x 2.5 x 1.4? (183 x 63.6 x 35.6mm) (H x W x D) |
Jaw opening |
0.9? (23mm) |
Standards |
IEC 1010 Category III 300V, Category II 600V |
|
|
EXTECH 380940 400A True RMS Watt Clamp-on Measures Watts, Current, and Voltage.
EXTECH 380940-NIST 400A True RMS Watt Clamp-on with NIST Measures Watts, Current, and Voltage.
General Specifications |
Display |
3-3/4 (4000 count) Digit LCD with 40 segment bargraph |
Functions |
Watts, ACA, DCA, ACV, DCV, Frequency |
Polarity |
?-? indicates negative polarity |
Current sensor |
Hall effect sensor type |
Overload indication |
Left blinking digit |
DCA zero adjust |
One touch zero key Display rate ; 2 readings/second (20 readings/second for bargraph) |
Display rate |
2 readings/second (20 readings/second for bargraph) |
Auto Power Off |
30 minutes after power ON |
Battery |
Two 1.5V AA batteries |
Operating temp. |
4 ° F to 122 ° F (-10 v C to 50 ° C) |
Operating Humidity |
< 85% RH |
Power consumption |
Approximately 10mA DC |
Weight |
6.7 oz. (190g) including battery |
Dimensions |
7.2 x 2.5 x 1.4? (183 x 63.6 x 35.6mm) (HWD) |
Jaw opening |
0.9? (23mm) |
Standards |
IEC 1010 Category III 300V, Category II 600V |
|
|
EXTECH 382400 Flexible True RMS 3000A AC Current Clamp Flexible 24" (610mm) probe easily wraps around bus bars and cable bundles
EXTECH 382400-NIST Flexible True RMS 3000A AC Current Clamp Flexible 24" (610mm) probe easily wraps around bus bars and cable bundles
Description:
Specifications Range Max Resolution Basic Accuracy AC Current 3 to 3000A 0.1A ±1% AC Voltage 4 to 600V 0.1V ±0.5% Frequency 45 to 65Hz 0.1Hz ±0.2Hz Display Dual 4000 count LCD Probe 24" (610mm) long, 0.55" (14mm) diameter Meter 5.1 x 3.15 x 1.7" (130mm x 80mm x 43mm) Weight 0.95lb (430g
|
|
EXTECH MA620-K: Industrial DMM/Clamp Meter Test Kit CAT IV MultiMeter, True RMS Clamp Meter with integrated AC Voltage Detector
- Kit includes:
- EX505 - Industrial grade, CAT IV-600V, 4000 count display, waterproof, drop-proof, rugged multimeter with True RMS functions
- MA620 - 600A True RMS 6000 count AC Clamp-on MultiMeter with built-in non-contact AC Voltage Detector, test leads and temperature probe
- Set of double molded professional test leads and magnetic hanging strap for the multimeter
- Type K thermocouple bead probe and Type K to Banana Input Adaptor
- Supplied in a soft carrying case that provides protection and organization for the meters whenever they are needed
|
|
EXTECH 42515-T 13:1 Wide range IR Thermometer with Pipe Clamp Probe
Description:
42515-T: Wide Range IR Thermometer with Type K input and Pipe Clamp 13:1 Wide range IR Thermometer with Pipe Clamp Probe Features:
■Includes 42515 Infrared Thermometer (-58 to 1472°F / -50 to 800°C) ◦13:1 distance to target ratio, laser pointer for easy targeting ◦Type K input for surface temperature measurements: -58 to 2498°F (-50 to 1370°C) ◦Memory stores up to 20 readings, MAX/MIN/AVG/DIF functions ◦Adjustable high/low visual and audible alarm ◦Complete with 9V battery, Type K bead wire probe and carrying case
■Includes TP200 Type K Pipe Clamp Temperature Probe (-4 to 200°F / -20 to 93°C) ◦Spring-loaded jaw for secure grip on pipe from 0.25" (6.35mm) to 1.5" (38mm) diameter ◦Measurement range: -4 to 200°F (-20 to 93°C) ◦Accuracy: ±3.6°F (1.8°C)
|
|
EXTECH MA640-K: Phase Rotation/Clamp Meter Test Kit True RMS Clamp Meter, 3-phase rotation tester, and CAT IV AC Voltage Detector
Features:
- Kit includes:
- MA640 - 600A True RMS 6000 count AC/DC Clamp-on MultiMeter with built-in non-contact AC Voltage Detector, test leads and temperature probe
- 480400 - 3-Phase Rotation Tester with multiline LCD display, durable double-molded housing, and easy-to-open wide-jaw alligator clips
- DV25 - Dual Range AC Voltage Detector (24 to 1000VAC/100 to 1000VAC) + Flashlight with Audible/Visual indication, double-molded housing, and CAT IV-1000V safety rating
- Set of double molded professional test leads
- Type K thermocouple bead probe and Type K to Banana Input Adaptor
- Supplied in a soft carrying case that provides protection and organization for the meters whenever they are needed
|
|
EXTECH TK730 : Professional Clamp Meter Test Kit
True RMS Professional Clamp with InfraRed Thermometer for non-contact Temperature measurements
- Professional kit includes:
- EX730: 800A True RMS AC/DC Clamp Meter (0.1A Resolution, ±3% AC accuracy)
- 480172: AC line splitter enables use of a clamp meter to measure AC Current on a 2-wire or 3-wire power cord to 15A
- DV20: Non-contact AC Voltage Detector (detects Voltage from 100 to 600V)
- 42510: Mini InfraRed Thermometer (-58 to 1000°F/-50 to 538°C)
- Set of test leads and Type K Thermocouple
- UL approved on EX730, DV20, and 480172
- Dimensions: 9.5x6.8x2.8 (241x173x71mm)
|
|
EXTECH 380976-K: Single Phase/Three Phase 1000A AC Power Clamp Meter Kit
Measures Current, Insulation Resistance, Temperature (Type K) and Power
Features:
-
1.6" (40mm) clamp jaw opening and large dual LCD display (9999 count)
-
Measures 1/3-Phase True Power (kW), Apparent Power (kVA), Reactive Power (kVAR), Horsepower (HP), Power Factor, and Phase Angle with Lead/Lag indicator
-
AC+DC µA current with 10nA resolution for flame rod tests
-
Auto Detect AC/DC Voltage measurements with simultaneous frequency display
-
Capacitance to 7000µF with 0.001µF resolution
-
High Resistance tests to 100MOhm
-
Type K, °C/°F switchable, temperature to 1000°F
-
Diode and Continuity tests
-
Complete with test lead kit, general purpose Type K thermocouple probe, carrying case, and 9V battery
|
|
EXTECH EX820 Clamp-on multimeter with built-in non-contact InfraRed Thermometer
EXTECH EX820-NISTL Clamp-on multimeter with built-in non-contact InfraRed Thermometer NISTL Certificate Included.
Features:
- AC Current
- True RMS
- Type K Thermometer
- Non-contact InfraRed Temperature measurements with laser pointer
- Peak hold captures inrush currents and Transients
- MultiMeter functions include
- AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, and Continuity
- 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
- 4000 count backlit dual display
- Features include Data Hold and Min/Max
- Autoranging with manual range button
- Auto Power off
- Complete with test leads, 9V battery, Type K probe (-4 to 482°F/-20 to 250°C), and belt holster
Description
Clamp-on multimeter with built-in non-contact InfraRed Thermometer.
General Specifications |
IR Temperature |
-58 to 518ºF -50 to 270ºC |
AC Current |
0.1 to 1000A |
DC Current |
NA |
AC Voltage |
0.1mV to 600V |
DC Voltage |
0.1mV to 600V |
Resistance |
0.1 to 40M Ω; |
Capacitance |
0.001nF to 40,000µF |
Frequency |
0.001kHz to 4kHz |
Type K Temperature |
-4 to 1400°F -20 to 760°C |
Continuity |
Yes |
Inrush |
Yes |
Diode |
Yes |
Dimensions/Wt. |
10.6x4.3x2" (270x110x50mm) |
Weight |
13.6oz (386g) |
|
< กลับ >
|